Recall 96V-221: 1996–1997 Amtran RS3302, 1996–1997 Amtran RS3505 and 1 more
AMERICAN TRANSPORTATION CORP. recall for parking brake, reported to NHTSA on Nov 4, 1996, covering about 194 vehicles.
The problem
The air/spring actuated parking brake chambers manufactured by midland (Date code 145b6k) were filled with the wrong lubrication. The improper lubricant causes the seals within the chamber to fail and results in loss of air. If air pressure drops to 55 PSI the spring within the chamber will automatically apply the parking brake.
The risk
If air pressure drops below 55 PSI and the operator does not heed the low air pressure warning and continues to drive, the parking brake will apply. This can cause the parking brake lining to overheat and prematurely wear. When the bus is parked and the brake applied, the parking brake would not operate properly.
The fix
Dealers (Or owners) will inspect the brake chambers for the suspect date code. If the chamber has this code, the parking brake chamber will be replaced.
Notes
Owner notification:owner notification began october 28, 1996.note:owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact amtran at 1-800-843-5615.also contact the national highway traffic safety administration's auto safety hotline at 1-800-424-9393.
Recall details
| Manufacturer | AMERICAN TRANSPORTATION CORP. |
|---|---|
| Component | Parking Brake › Driveline › Air |
| Recall started by | the manufacturer |
| NHTSA campaign number | 96V221000 |
Vehicles in this recall
| Vehicle | Model years | |
|---|---|---|
| Amtran RS3302 | 1996, 1997 | All years |
| Amtran RS3505 | 1996, 1997 | All years |
| Amtran RS3708 | 1996, 1997 | All years |
Not every vehicle of these model years is included. Enter your VIN at nhtsa.gov/recalls ↗ or ask a dealer.
Frequently asked questions
What is recall 96V-221?
The air/spring actuated parking brake chambers manufactured by midland (Date code 145b6k) were filled with the wrong lubrication. The improper lubricant causes the seals within the chamber to fail and results in loss of air. If air pressure drops to 55 PSI the spring within the chamber will automatically apply the parking brake.
How is recall 96V-221 fixed?
Dealers (Or owners) will inspect the brake chambers for the suspect date code. If the chamber has this code, the parking brake chamber will be replaced.
Is the recall repair free?
Yes. Safety recall repairs are free at authorized dealers. Check whether your vehicle is included with its VIN at nhtsa.gov/recalls.